Indoor Air Quality & Ventilation Upgrades

Filtration, outside air and exhaust upgrades that meet ASHRAE 170 and 62.1 — verified with airflow and pressure documentation.

Overview

Air quality work is only credible when it is measured. CMI approaches IAQ as an engineering scope: measure the outside air actually delivered, the exhaust actually removed, filter loading against fan capacity, and the pressure relationships between spaces — then upgrade what the data says is deficient and document the result.

Typical scope includes filtration upgrades to MERV 13/14/15 or HEPA with fan and static pressure analysis, outside air economizer and damper repair, dedicated outside air systems, exhaust and make-up air corrections, humidity control and dehumidification, UV-C and bipolar ionization where appropriate, duct cleaning coordination, and CO2 demand-control ventilation tied into the BAS.

For healthcare and therapeutic facilities, we work to ASHRAE 170 and CDPH requirements: air changes per hour, positive and negative pressure rooms, isolation and protective environment rooms, pharmacy compounding suites under USP 797/800, procedure and sterile processing areas. Every upgrade leaves a verification report you can hand to a surveyor.

What's included

Scope & capabilities

  • Ventilation assessments: OA/EA measurement, ACH verification, pressure mapping
  • Outside air, economizer, damper and DOAS scope
  • Positive/negative pressure room construction and certification support
  • Humidification, dehumidification and reheat control
  • CO2 demand-control ventilation and BAS integration
  • Filtration upgrades with fan, static pressure and housing analysis
  • Exhaust and make-up air corrections for labs, kitchens and soiled utility
  • USP 797/800 compounding room mechanical scope
  • UV-C, needlepoint ionization and photocatalytic options where justified
Specifications

The technical envelope

Standards
ASHRAE 170, ASHRAE 62.1, CDPH, USP 797/800, Title 24
Filtration
MERV 8 – 16, HEPA with challenge testing support
Verification
Airflow, ACH, pressure differential and humidity documentation
Monitoring
Room pressure monitors, CO2 and RH sensors on the BAS
Certification
Third-party certifier coordination for critical rooms
Where it applies

Facility types

Hospitals, surgery centers and dialysis clinics
Compounding pharmacies and therapeutic production suites
Research and teaching laboratories
Schools and childcare facilities
Offices with tenant IAQ commitments and WELL/LEED goals
Questions owners ask

IAQ & Ventilation Upgrades — straight answers

Can our existing air handler carry MERV 14 or HEPA filters?
Sometimes, and sometimes not — that is exactly what we check first. We measure current static pressure and fan capacity, model the added resistance, and tell you whether the upgrade needs a fan, motor, drive or housing change to avoid starving the zones.
Do you certify pressure relationships for isolation rooms?
We perform and document the mechanical work and airflow verification and coordinate the independent certifier where one is required. You receive the airflow, ACH and differential-pressure documentation with the closeout package.
Is UV-C or ionization worth installing?
Only where filtration, outside air and pressure relationships are already correct. We will tell you plainly when a device is being sold as a substitute for ventilation that simply needs to be repaired.
IAQ & Ventilation Upgrades

Get a number you can budget against

We walk the plant before we price it. You get equipment condition, options, phasing and a schedule — not a guess with a contingency wrapped around it.