Hydronic piping, pumps and valves in a mechanical room
Piping, Steam & Fabrication

Hydronic Piping, Pumps & Plant Renewal

Chilled, hot and condenser water piping, pump and header replacement, variable-flow conversions and valve packages.

Overview

Hydronic systems fail slowly and expensively: corroded headers, leaking control valves, seized balancing valves, worn pump seals and impellers, air that never gets purged, and three-way valves quietly mixing supply and return. The result is a plant running full-out to satisfy zones that never get enough flow.

CMI renews hydronic systems end to end — chilled water, heating hot water, condenser water, glycol and process loops. That includes welded and grooved piping replacement, header rebuilds, isolation and control valve packages, strainers, air separators, expansion tanks, pump replacement and rebuild, mechanical seal and coupling work, base-mounted and inline pumps, VFDs and premium-efficiency motors.

Where it makes sense we convert constant-volume plants to variable flow — variable-primary or high-delta-T pumping with proper minimum-flow protection, differential-pressure control and BAS sequences — which typically cuts pumping energy sharply and stabilizes the whole distribution system. We coordinate chemical treatment and cleaning so a new loop does not inherit the old one's corrosion.

What's included

Scope & capabilities

  • Welded steel and grooved piping replacement, header and manifold rebuilds
  • Pump rebuilds: seals, bearings, couplings, impeller trim and alignment
  • Variable-primary and high-delta-T flow conversions
  • Expansion tanks, air management and glycol fill and makeup systems
  • Flushing, chemical cleaning and water treatment program coordination
  • Base-mounted, inline, vertical turbine and end-suction pump replacement
  • VFDs, premium-efficiency motors and differential pressure control
  • Control, balancing and isolation valve replacement; strainers and separators
  • Insulation, jacketing, seismic bracing and code-compliant supports
Specifications

The technical envelope

Pipe sizes
1/2" – 30" welded, grooved and flanged
Pump range
1 – 500 HP
Conversions
Constant to variable flow, primary/secondary rework
Testing
Hydrostatic testing, flushing and flow verification
Verification
Hydronic balancing report at completion
Where it applies

Facility types

Hospital and lab central plants
Campus chilled and hot water distribution
High-rise and mixed-use hydronic risers
Process cooling loops in manufacturing
Data center chilled water systems
Questions owners ask

Hydronic Piping & Pumps — straight answers

Some zones never get enough flow — is that a pump problem?
Usually not. It is more often a closed or seized balancing valve, a fouled coil, a leaking three-way valve, air in the loop, or a differential-pressure setpoint that ignores the critical zone. We measure the distribution before recommending a larger pump.
Can you replace pumps without shutting down the plant?
In a redundant plant, yes — one pump at a time with proper isolation. In a single-pump system we plan a short outage or install a temporary pump and piping, generally on a weekend.
Is a variable-flow conversion worth doing?
Pumping energy varies with the cube of flow, so on constant-volume systems with meaningful part-load hours the savings are large and the payback is usually short. We model your load profile before recommending it.
Hydronic Piping & Pumps

Get a number you can budget against

We walk the plant before we price it. You get equipment condition, options, phasing and a schedule — not a guess with a contingency wrapped around it.

Request a proposal(858) 752-4540