Skip to content
Institutional boiler room with firetube boilers, headers and pumps
HVAC Systems & Equipment

Commercial & Institutional Boiler Installation and Repair

Firetube, watertube and condensing boilers — installation, retubing, burner service and combustion tuning to code.

Overview

Boilers carry sterilization, humidification, domestic hot water and heating loads that a facility cannot improvise around. CMI installs, repairs and maintains firetube and watertube steam boilers, hot water boilers and high-efficiency condensing plants — including the low-NOx burner and controls work that California air districts require.

On the service side we handle burner overhauls and combustion tuning with analyzer readings, refractory repair, tube replacement and retubing, low-water cutoff and control replacement, feedwater and deaerator systems, chemical treatment coordination, safety valve replacement and annual inspection support. We troubleshoot flame safeguard and burner management systems rather than swapping parts until the lockout clears.

On the installation side we take the plant end to end: load calculation and boiler selection, demolition, rigging into tight basement rooms, stacks and breeching, gas train and piping, condensate and feedwater systems, near-boiler piping done right, controls and lead/lag sequencing, then combustion tuning, permitting support with the San Diego County Air Pollution Control District, and operator training.

What's included

Scope & capabilities

  • Firetube, watertube, cast-iron sectional and condensing boiler installation
  • Burner overhaul, low-NOx burner retrofits and combustion analysis and tuning
  • Feedwater, deaerator, condensate receiver and blowdown separator systems
  • Lead/lag, outdoor reset and BAS integration for multi-boiler plants
  • Boiler retubing, tube replacement, refractory and gasket repair
  • Burner management, flame safeguard and boiler control replacement
  • Gas train, stack, breeching and combustion air scope
  • Safety valve replacement, annual inspection support and jurisdictional coordination
Specifications

The technical envelope

Capacity range
500 MBH – 60,000 lb/hr steam
Pressures
Low-pressure heating through 150 psi steam
Fuels
Natural gas, dual fuel, propane backup
Compliance
SDAPCD permitting support, ASME, state boiler inspection
Emergency service
24/7 for steam and heating plant failures
Where it applies

Facility types

Hospital steam and sterilization plants
Pharmaceutical and therapeutic process heating
Central heating hot water plants on campuses
Commercial laundries and kitchens
Government and military facilities
Hotels and high-rise domestic hot water plants
Questions owners ask

Boiler Installation & Repair — straight answers

Do you provide temporary steam during a boiler replacement?
Yes. For hospitals and process facilities we plan rental boiler placement, temporary piping, condensate return and controls so sterilizers, humidification and domestic hot water stay online through the changeover.
Can you handle low-NOx requirements and air district permitting?
We select compliant burners, provide the emissions and equipment data, and support the permit application and source testing with San Diego County APCD. Combustion tuning results are documented with analyzer printouts.
Is retubing worth it versus replacing the boiler?
It depends on shell condition, age, efficiency and code exposure. We inspect, give you both numbers — retube cost against a new plant with the resulting fuel savings and permitting path — and let the life-cycle cost decide.
Boiler Installation & Repair

Get a number you can budget against

We walk the plant before we price it. You get equipment condition, options, phasing and a schedule — not a guess with a contingency wrapped around it.

Request a proposal(858) 752-4540

24/7 emergency dispatch